BOILER SYSTEM
SYSTEM CONDITION:
Good
Good. The boiler unit was run through a complete cycle.
The safety controls were observed. The boiler was operated by turning
up the thermostat, and then turned back to its original setting.
Dirty
Unit is due for a normal service maintenance cleaning and tune up.
Fair
The boiler unit was run through a complete cycle.
The safety controls were observed. The boiler was operated by turning
up the thermostat, and then turned back to its original setting
Dirty
Unit is due for a normal service maintenance cleaning and tune up.
OldBudget Keep
in mind the advanced age of this unit = The upgrade to a new unit is
inevitable and should be planned and budgeted for.
ShortCycle The unit
short cycles which indicates that the unit needs repair = Recommend further
evaluation/repair by a licensed heating contractor.
EvalChambe There is
ash, soot, and debris in the bottom of the combustion chamber which could be
a sign of a cracked/rusted combustion chamber = Recommend further evaluation
by a boiler specialist to verify the integrity of the combustion chamber.
Inefic
$$$ This unit is
older and very inefficient by today's standards.
With the rising fuel costs consideration should be given to upgrading
the unit if you plan on owning the dwelling long enough to recoup the
investment = Consult with a boiler specialist on upgrade costs and payoff
ratios.
Poor
Poor = Recommend further evaluation by a boiler specialist.
Pilot Off
The unit was not tested = Pilot Shut Off.
Gas Off
The unit was not tested = Gas Shut Off.
>85 DNT
Unable to evaluate the boiler when the ambient air temperature is
above 85 degrees.
Repair
Repairs are needed to the system = Recommend further
evaluation/repair by a boiler specialist.
HEATING AREA:
TYPE:
Boiler
Boiler system with room heat radiators.
BoilerRad Boiler
system with radiant room heating.
ClosedSyst This
system is a closed boiler system. This
means that the water is used solely for the heating system and is not part
of the culinary hot water supply.
OpenSystem This
system is an open boiler system. This
means that the water that is heated is also used for the culinary hot water
supply.
ESTIMATED LIFESPAN:
CastIron35 According
to industry experts, the average life of a cast iron boiler in the U.S. is
35 years. Us this estimate
as a general guideline. Many
factors can affect the operation of this system and it is possible for the
system to fail at any time.
Steel25 According
to industry experts, the average life of a steel boiler in the U.S. is
25 years. Us this estimate
as a general guideline. Many
factors can affect the operation of this system and it is possible for the
system to fail at any time.
1520Exchan According
to industry experts, the average life of a heat exchanger in the U.S. is 15
to 20 years. Us this estimate
as a general guideline. Many
factors can affect the operation of this system and it is possible for the
system to fail at any time.
15Exchang According
to industry experts, the average life of a heat exchanger in the U.S. is 15
years.
Unknown
The remaining life of this boiler impossible to predict.
HEATING ZONES:
1 Zone This system uses 1
heating zone.
2 Zones
This system uses 2 zones.
3 Zones
This system uses 3 zones.
4 Zones
This system uses 4 zones.
5 Zones
This system uses 5 zones.
6 Zones
This system uses 6 zones.
Dead 1
One zone did not heat up as designed = Recommend further
evaluation/repair by a boiler specialist.
Dead 2
Two zones did not heat up as designed = Recommend further
evaluation/repair by a boiler specialist.
Dead 3
Three zones did not heat up as designed = Recommend further
evaluation/repair by a boiler specialist.
1Unused
There is one unused zones for future expansion to the system.
2 Unused
There are two unused zones for future expansion to the system.
3 Unused
There are three unused zones for future expansion to the system.
4 Unused
There are four unused zones for future expansion to the system.
THERMOSTATS:
Manual
Manual models.
Digital
Digital models.
SetBack
Set-back programmable models.
1 only
There is only 1 thermostat installed.
1 unit There is 1 thermostat
installed.
2 units
2 thermostats were found.
3 units
3 thermostats were found.
4 units
4 thermostats were found.
5 units
5 thermostats were found.
6 units
6 thermostats were found.
7 units
7 thermostats were found.
8 units
8 thermostats were found.
BOILER CONDITION:
Good
Good. The boiler unit was run through a complete cycle.
The safety controls were observed. The boiler was operated by turning
up the thermostat, and then turned back to its original setting.
Dirty
Unit is due for a normal service maintenance cleaning and tune up.
Fair The boiler
unit was run through a complete cycle.
The safety controls were observed. The boiler was operated by turning
up the thermostat, and then turned back to its original setting.
Dirty
Unit is due for a normal service maintenance cleaning and tune up.
OldBudget Keep
in mind the advanced age of this unit = The upgrade to a new unit is
inevitable and should be planned and budgeted for.
ShortCycle The
unit short cycles which indicates that the unit needs repair = Recommend
further evaluation/repair by a boiler specialist.
EvalChambe There
is ash, soot, and debris in the bottom of the combustion chamber which could
be a sign of a cracked/rusted combustion chamber = Recommend further
evaluation by a boiler specialist to verify the integrity of the combustion
chamber.
Inefic $$$ This
unit is older and very inefficient by today's standards.
With the rising fuel costs consideration should be given to upgrading
the unit if you plan on owning the dwelling long enough to recoup the
investment = Consult with a boiler specialist on upgrade costs and payoff
ratios.
Poor
Poor = Recommend further evaluation by a boiler specialist.
Pilot Off The
unit was not tested = Pilot Shut Off.
Gas Off
The unit was not tested = Gas Shut Off.
>85 DNT
Unable to evaluate the boiler when the ambient air temperature is
above 85 degrees.
Repair Repairs are needed to the
system = Recommend further evaluation/repair by a boiler specialist.
BRAND:
Lennox
Lennox.
Lennox Pul Lennox
Pulse.
Rheem
Rheem.
Day&Night
Day & Night.
Bryant
Bryant.
Payne
Payne.
Carrier
Carrier.
Tempstar
Tempstar.
Armstrong Armstrong.
Amana
Amana.
Comfortmas Comfortmaster.
Janitrol
Janitrol.
Heil
Heil.
Unmarked
No brand label was found on the unit.
APPROXIMATE AGE:
Original
Appears to be the original unit.
1-3
Unit appears to have been recently upgraded.
Over 15
The unit is over 15 years of age.
Over 25
This unit is over 25 years of age.
Over 35
This unit is over 35 years of age.
2001
2001
2000
2000
1999
1999
1998
1998
1997
1997
1996
1996
1995
1995
1994
1994
1993
1993
1992 1992
1991
1991
1990
1990
1989
1989
1988
1988
1987
1987
1986
1986
1985
1985
1984 1984
1983
1983
BURNERS:
PoorFlame There
is a poor burning flame pattern = Recommend further evaluation, service
cleaning, and tune-up.
Erratic
The flame pattern is very erratic and needs to be adjusted for a
clean burn= Recommend further evaluation/repair by a licensed Heating
Ventilation Air Conditioning technician.
FlameDefle The
burner flames deflect when the blower motor turns on. This is a sign of a probable crack in the combustion chamber.
Recommend further evaluation/repair by a boiler specialist.
HighCOCCha Elevated
levels of carbon monoxide were measured inside the top of the combustion
chamber = Recommend further evaluation/repair by a licensed boiler specialist.
HighCOFlue Elevated
levels of carbon monoxide were measured inside the exhaust flue = Recommend
further evaluation/repair by a boiler specialist.
CORegister Elevated
levels of carbon monoxide were measured at the interior heat register =
HAZARD = Recommend further evaluation/repair by a licensed boiler specialist.
90+
90+ efficiency heaters have sealed combustion chambers preventing
visual inspection of the burner flames.
Evaluate
Recommend further evaluation/repair by a boiler specialist.
BOILER
PRESSURE:
H20<28 The pressure is below the
recommended 28 psi maximum.
H20>28HAZ The pressure is above the
recommended 28 psi maximum= Recommend further evaluation by a
boiler specialist.
Steam<15 The pressure is below the recommended 15
psi maximum.
Steam>15HAZ The pressure is above the recommended 15
psi maximum= Recommend further evaluation by a boiler
specialist.
NoGauge
The recommended pressure gauge is NOT installed.
PRESSURE RELIEF VALVE:
Installed The recommended pressure relief valve is
installed on the system.
DrainFloor The
drain pipe is routed to the floor as designed.
DrainCrawl The
drain pipe is routed to the crawl space as designed.
DrainOutsi The
pressure relief valve is drained to the outside as designed.
NoneHazard No
pressure relief valve is installed on the unit = Potential Hazard =
Recommend the immediate installation.
Extend DL The
pressure relief valve drain line ends prematurely.
This is a SAFETY HAZARD. We
recommend the drain line be extended to the exterior or within 6" of
the floor to prevent accidental scalding.
NoDrainLin The
pressure relief valve is missing a drain line.
This is a Safety Hazard. We
recommend the addition of a proper drain line that is either routed outside
or within 6" of the floor to prevent accidental scalding.
Reduced
The pressure relief valve drainpipe is unsafely reduced in size =
Recommend immediate further evaluation/repair by a licensed Plumber.
If the valve has a 3/4" discharge size, then the drain line
cannot be reduced from 3/4" because when the line is needed it needs to
be able to immediately blow off pressure build up.
Uphill The pressure relief valve
drain is routed uphill = Potential Hazard = Recommend immediate further
evaluation/repair by a licensed Plumber.
Routing the line uphill can cause a collection of water and corrosion
on the outside of the valve causing seizure of the valve.
Reused
The pressure relief valve was unsafely reused from the previous unit. The valves corrode with age and stop working properly =
Immediately upgrade the valve for safety.
Dripping
The pressure relief valve is currently dripping = Upgrade the
valve.
Damaged
The pressure relief valve is damaged = Repair/Replace immediately for
safety.
WATER
TEMPERATURE:
OldH20>140 The temperature
of the water in this older hot water boiler system exceeds the recommended
140 degree limit =
Recommend further evaluation/repair by a boiler specialist.
NewH20>160 The temperature
of the water in this newer hot water boiler system exceeds the recommended
160 degree limit =
Recommend further evaluation/repair by a boiler specialist.
H20>240Haz The temperature
of the water in this hot water boiler system exceeds 240 degrees =
Hazard =
Recommend further evaluation/repair by a boiler specialist.
Above220
The temperature is above the recommended 130-220 degree standards =
Recommend further evaluation by a boiler specialist.
Below 130 The
temperature is below the recommended 130-220 degree standards = Recommend
further evaluation by a boiler specialist.
NoGauge
The recommended temperature gauge is NOT installed.
EXPANSION TANK:
Installed The recommended expansion tank is
installed on the system = Did Not Test.
None The
recommended expansion tank was not identified on the system = Recommend
further evaluation/repair by a boiler specialist.
Leaks There is
evidence of leaking from the expansion tank. This usually means that
the tank needs to be replaced = Recommend further evaluation/repair by a
boiler specialist.
STEAM BOILER SITE GLASS:
Installed The
recommended steam boiler site glass is installed on the system.
DirtyH20 The liquid in the site glass is dirty which
indicates that the system needs servicing and possible flushing of the
system.
Fluctuate Rapidly fluctuating water levels were observed
in the site glass and this may mean danger = Immediate evaluation/repair by
a boiler specialist is recommended.
BLEEDER VALVE:
Installed The
recommended system bleeder valve is installed on the system = Did Not Test.
None The recommended
bleeder valve is not installed on the system = It is recommended that a
bleeder valve be installed on the system by a boiler specialist.
FILL VALVE:
Installed There is a fill valve present on
the system = Did Not Test.
NoFillValve The recommended fill valve is not installed on the system.
NoBackFlow The recommended backflow prevention valve on the water
supply system is not installed.
BackFlowYes The recommended backflow valve is installed on the system = Did
Not Test.
LOW
WATER CUTOFF:
Installed The
recommended low water cut-off valve is installed = Did Not Test.
Definition The low water cut-off valve shuts down the
system if the water level gets too low. This safety feature helps to
prevent damage to the boiler and/or possible explosion.
NotPresent The recommended low water cut-off valve is not
installed on this system. It is recommended that the system be further
evaluated by a boiler specialist and have the needed low water cut-off
installed.
CIRCULATION
PUMP(S):
Smooth
Operates smoothly.
CurrenLeak Leak
evidence was observed = Repair/replace.
PastLeaks There
is evidence of past leaks = Monitor and repair future leaks as needed.
DNT
The circulation pump was not tested.
1 Pump
There is one circulation pump installed.
2 Pumps
There are two circulation pumps installed.
3 Pumps
There are three circulation pumps installed.
4 Pumps
There are four circulation pumps installed.
5 Pumps
There are five circulation pumps installed.
6 Pumps
There are six circulation pumps installed.
Vibrates The circulation pump is
vibrating = Repair/replace.
CIRCULATION PIPING:
Types The following types
of piping were visible in the boiler liquid distribution lines:
Copper
Copper
Galvanized Galvanized
Rubber
Rubber
PEX
PEX - Cross linked polyethylene
Polybutyle Polybutylene
- Due to some failures of this piping on boiler systems we recommend that a
boiler specialist further evaluate the system to verify the integrity of the
piping.
RubberLife The
anticipated lifespan of rubber boiler piping is unknown.
COMBUSTIBLE CLEARANCE:
Good
Clearance to combustibles is Good.
Fair Clearance to
combustibles is Fair.
Poor
clearance to combustibles is Poor.
GAS
SHUT-OFF:
Hand
An easy operate hand shut-off valve is installed on the gas line.
HandFlex
An easy operate hand shut-off valve is installed on the gas line. A
flexible gas line is installed.
HandNOFlex An
easy operate hand shut-off valve is installed on the gas line. A flexible gas line is NOT installed. Modern building standards recommend the use of a flexible gas
connector line = Consider the upgrade.
WrenchFlex The
gas hook-up is equipped with a shut-off valve that requires a wrench to
operate. Modern building
standards recommend the use of a hand shut-off type gas control valve =
Consider the upgrade. A
flexible gas line is installed.
WrenNOFlex The
gas hook-up is equipped with a shut-off valve that requires a wrench to
operate. The recommended
flexible gas line is not installed.
NoShutOff A
gas shut-off is not installed on the gas line = Potential Hazard.
Modern building standards recommend the upgrade installation of an
easy off hand operated gas valve.
HandValve An
easy operate hand shut-off valve is installed on the gas line.
WrenchValv The
gas hook-up is equipped with a shut-off valve that requires a wrench to
operate.
No Flex
A flexible gas line is not installed.
Modern standards recommend the installation upgrade of a flexible gas
line.
BrassLine The
unit is equipped with a flexible gas line.
The type of flexible gas line used is an uncoated brass. The Consumer Product Safety Commission issued a news warning
in September 1997 that all uncoated brass flexible gas line connectors
should be upgraded with newer plastic coated or stainless steel models.
The older brass models are prone to cracking or leaking and can cause
a serious gas leak, explosion or fire.
Consult an licensed heating contractor for the installation of a new
flexible line.
OldFlex
The flex line was not upgraded when the new appliance was installed.
FlexCase
The flex line of incorrectly passes through the case of the furnace. In the event of an earthquake or movement, the case can
easily shear the flexible gas line. It
is recommended for that this be repaired by a licensed heating contractor.
VENTING:
ComExGood The
combustion and exhaust venting appear to be Good.
ComInterio The
combustion air is provided by the home's interior.
No exterior or attic ventilation air source is provided.
ComExterio The
combustion air is provided from the home's exterior.
No obstructions were identified.
ComAttic
The combustion air is provided from the home's attic.
No obstructions were identified.
ComInadequ Combustion
venting appears to be inadequate. This
can starve the unit and cause an unsafe backdrafting condition = Recommend
further evaluation/repair by a licensed heating contractor for safety.
ComPoor
Combustion venting is Poor. This
starves the unit and causes an unsafe backdrafting condition = Recommend
further evaluation/repair by a licensed Heating Ventilation Air Conditioning
contractor for safety.
ComStuffed The
fresh air venting is blocked off = Open up to restore the flow of fresh air
= Safety Hazard.
PrCrawlVen There
is inadequate ventilation for the gas appliances in the crawl space.
ExhaustGd Exhaust
venting is Good.
TapeJoints The
exhaust flue joint with the main vertical vent flue is not adequately sealed
= Hazard = This allows exhaust gases to escape into the interior of the home
= Recommend repair/resealing of the leaking joint.
ExhaustFai Exhaust
venting is Fair.
ExhaustPoo Exhaust
venting is Poor.
DryerRoom The
clothes dryer is located in the same room as the gas appliance. Clothes dryers suck air from the room and discharge it to the
exterior. If the door is shut
to this room, this can create a starved fresh air condition that can affect
the burn of a gas flame.
Hor/Neg
Horizontal or negative fall on the exhaust vent line = Hazard =
Recommend repair to prevent a backflow of the exhaust gases.
Less 6" Cv The
exhaust flue is routed to close to flammable surfaces.
Single walled "C" vents are rated to need at least 6"
clearance to combustibles = Recommend further evaluation/repair by a
licensed heating contractor.
Less 2" Bv The
exhaust flue is routed to close to flammable surfaces.
"B" vents are rated to need at least 2" clearance to
combustibles = Recommend further evaluation/repair by a licensed heating
contractor.
Dryw2Close The
exhaust vent flue is routed to close to drywall which is also considered a
combustible material = Recommend further evaluation/repair by a licensed
HVAC.
Carp2Close The
exhaust vent flue is routed to close to interior carpet which is a
combustible material = Recommend further evaluation/repair by a licensed
heating contractor.
FlueBedroo The
exhaust vent flue is routed openly through a bedroom = Safety Hazard =
Recommend further evaluation/repair by a licensed heating contractor.
COMBUSTION CHAMBER:
DNE
Did Not Evaluate. The
complete evaluation of Combustion Chambers/Heat Exchangers is technically
exhaustive and is beyond the scope of this evaluation.
AshSoot
Ash, soot and debris was noted in the burn chamber.
Rust
There was rust noted in the combustion chamber which indicates some
deterioration of the combustion chamber.
Suspect
The combustion chamber shows sign of deterioration = Recommend a full
combustion chamber evaluation to verify its integrity by a licensed Heating
Ventilation Air Conditioning technician.
Popping
Popping was heard during the warm-up cycle.
This may be a sign of a deteriorated combustion chamber.
WhiteCryst There
is a white crystal type of build-up on the combustion chamber = Recommend
further evaluation, cleaning and servicing by a licensed heating contractor.
90+
90+ efficiency heaters have sealed combustion chambers preventing
visual inspection.
AMBIENT AIR TEMPERATURE:
15
15 degrees.
20
20 degrees.
25
25 degrees.
30
30 degrees.
35
35 degrees.
40
40 degrees.
45
45 degrees.
50
50 degrees.
55
55 degrees.
60
60 degrees.
65
65 degrees.
70
70 degrees.
75
75 degrees.
80
80 degrees.
85
85 degrees.
90
90 degrees.
95
95 degrees.
100
100 degrees.
PLUMBING
LEAKS:
Above
There is a leak on the piping above the unit = Recommend Repair.
AboveValve There
is a leak on the valve above the unit = Recommend Repair.
SRV Drip
The pressure relief valve is dripping = Recommend Repair.
DrainDrip The
drain valve is dripping = Recommend Repair.
Replace
The boiler unit has failed = Recommend replacement of the unit.
RAISED
PLATFORM:
Yes
Yes
No
No = Potential Hazard
18"
It is recommended that the unit be installed so that the burner is at
least 18" off of the ground to prevent explosions.
RECOMMENDATION:
NoMaintena The
unit shows no evidence of recent maintenance.
Part of the normal maintenance of gas appliances is that they should
be serviced at least annually to ensure the integrity of the unit. It is recommended that you have this unit serviced,
evaluated, and retuned by a heating contractor before closing on the home.
YesMainten The
unit shows evidence of recent maintenance.
Part of the normal maintenance of gas appliances is that they should
be serviced at least annually to ensure the integrity of the unit.
HVACEvalu Recommend
further evaluation/repair by a licensed heating contractor.
OffGasCo The gas is currently shut off = We
recommend before closing on the home that, for your safety, you have the gas
turned on and have the gas appliances checked by either the Utility Company
or a licensed heating contractor.
Tune-up
Recommend a service tune-up/cleaning and further evaluation by a
licensed Heating Ventilation Air Conditioning technician.
This service is best performed before the home's closing, and will
improve the overall energy efficiency of the heating unit.
RecentMain The
unit shows evidence of recent maintenance.
RecMainten Regular
maintenance, as recommended by the manufacturer, is required for all
appliances. See the Owner's
Manual for details.
NOGreenSti The
now famous Questar "Green Sticker" is NOT present on this unit.
The "Green Sticker" verifies that this unit has been tuned
to operate at this elevation and with the current grade of natural gas.
Consideration should be given to having this unit serviced and tuned
up to perform at its most efficient level.
YESGreenSt The
now famous Questar "Green Sticker" is present on this unit.
This means that the unit has been adjusted for the lower grade of
natural gas that has been used in our area since 1998.
NoGSDone
The now famous Questar "Green Sticker" is NOT present on
this unit, but the installer has left the markings that indicate that the
unit has been tuned for the gas and elevation.
It is recommended that the settings be reverified during your normal
annual furnace service tune up.
EQUIPMENT
SIZE:
MODEL #:
SERIAL #:
REMARKS: